High Performance Liquid Chromatography system

High Performance Liquid Chromatography system

Product Details:

X

Product Description

HIGH PERFORMANCE LIQUID CHROMATOGRAPHY PH (HPLC)
  • DAD ( Diode Array Detector )
  • Fluorescence Detector
Application / Type For Analysis of Pesticide, Bench top software control integrated
  • Solvent Delivery Module 01 number
  • Type Quaternary Gradient
  • Operating Pressure 5800psi
  • Flow rate Upton to 10 ml/minute
  • Flow rate precision 0.1%RSD
  • Degasser Online / Built in
  • Accessories As per Manufacturers standard Including installation /fitting kit And compatible on line Solvent Degasser and manual injector (20 loop)
  • Spares Piston/plunger seal, piston/plunger Sea replacement kit, piston /plunger for pump, prime drain valve inlet and outlet check valve, solvent bottles and Tray in line filter and injector seal.
  • Diode Array Detector (DAD) with Temp. controlled cell 01 number
  • Number of Diode Elements 1024
  • Wave Length Range 190-900 nm
  • Wave length Accuracy ±1 nm
  • Noise Level 1x10 -5 AU
  • Spares Column mounting kit, D2 lamp/ Tungsten lamp, Glass windows, Gaskets, Flow cell (one each item 1No.
  • Fluorescence Detector 01 number
HIGH PERFORMANCE LIQUID CHROMATOGRA PH(HPLC ) (ETA-26B)
  • Application / Type For Analysis of mycotoxins (Aflatoxins), Bench top software control integrated
  • Solvent Delivery Module 01 number
  • Type Quaternary Gradient
  • Operating Pressure 5800psi
  • Flow rate Upton to 10 ml/minute
  • Flow rate precision 0.1%RSD
  • Degasser online / Built i
Accessories
  • Installation /fitting kit And compatible on line Solvent Degasser and manual injector.
  • Piston/plunger seal,
  • Piston/plunger Seal replacement kit,
  • Piston /plunger for pump,
  • Prime drain valve inlet and outlet check valve,
  • Solvent bottles and Tray in line filter and injector seal.
  • Diode Array Detector (DAD) with Temp. controlled cell
  • Number of Diode Elements 1024
  • Wave Length Range 190-900 nm
  • Wave length Accuracy ±1 nm
  • Noise Level 1x10 -5 AU
  • Spares Column mounting kit, D2 lamp/ Tungsten lamp, Glass windows, Gaskets, Flow cell (one each item) 1No.
  • Fluorescence Detector 01 number

Performance 

a) Raman (H2O) > 500 (noise reference measured at signal) Ex 350 nm, Em 397 nm, dark value 450 nm, standard flow cell

b) Raman (H2O) > 3000 (noise reference measured at dark value) Ex 350 nm, Em 397 nm, dark value 450 nm, standard flow cell.